Detects pulses in a Wave.
Details
Onsets and offsets follow the convention described under pulseDetection():
an onset is the first sample of a pulse and an offset the first sample after
it, so offset - onset is the length of the pulse in samples.
The detection thresholds a windowed energy, which rises over the half window
before a pulse begins and falls over the half window after it ends, so each
boundary is displaced outward by part of a half window and a duration is
overstated by part of a whole one. For a square pulse of 400 samples at the
default U of 120 the duration comes back as 492 rather than 400. Two pulses
separated by less than about U samples are reported as one, because the
energy does not fall below the threshold between them. Both effects shrink
with U, which is the time resolution the detection is asked for.
ste() computes a window only for the samples that hold a whole one, so the
half window at each end of the wave is not analysed and a pulse there is not
reported. Where both windows are wanted, as they are here, the longer of U
and V sets how much of each end is unanalysed.